MY63 Mastech
- Operating environment and condition:
- 1000V CAT.II, 600V CAT.III pollution grade: 2
- Elevation < 2000m
- Environment temperature and humidity: 0~40℃ (< 80% RH, < 10℃, it is not to be considered).
- Storage temperature and humidity: 0~60℃ (<70%RH, remove the battery).
- Temperature coefficient: 0.1 Accuracy/℃ (<18℃ or >28℃)
- The maximum allowable voltage between measurement end and ground: 1000V DC or 750V AC RMS
- Fuse protection: mA grade: Fuse F 250mA/250V; fuse with A grade FF10A/500V.
- Sampling rate: about 3 times/sec.
- Display: 3 1/2 digit LCD display, Automatically display unit symbols is accordance with measurement function grade.
- Over-range indication: LCD will show “1”.
- Low battery indication: When the battery voltage is lower than the normal operating voltage, “” will display on the LCD display.
- Input polarity indication: automatically display “-” symbol.
- Power supply: DC 9V
- Battery type: NEDA 1604, 6F22 or 006P.
- Outside measurement: 188mm(L)*93mm(W)*50mm(H).
- Weight: about 380g (include battery).
Features:
- Display: 2000 counts
- Auto Power Off
- Transistor hFE: 0~1000
- Diode: 2.8V
- Continuity Buzzer: <50Ω
- Data Hold
- Low Battery Display
Specification | Range | Accuracy |
DC Voltage | 200mV/2V/20V/200V | +-(0.5%+2) |
1000V | +-(0.8%+2) | |
AC Voltage | 2V/20V/200V | +-(0.8%+3) |
750V | +-(1.2%+3) | |
DC Current | 2mA/20mA | +-(0.8%+1) |
200mA | +-(1.5%+1) | |
10A | +-(2.0%+5) | |
AC Current | 20mA | +-(1.0%+5) |
200mA | +-(1.8%+5) | |
10A | +-(3.0%+7) | |
Resistance | 200Ω | +-(0.8%+3) |
2KΩ/20KΩ/200KΩ/2MΩ | +-(0.8%+2) | |
20MΩ | +-(1.0%+2) | |
200MΩ | +-(6.0%+10) | |
Capacitance | 2nF/20nF/200nF/2µF | +-(4.0%+3) |
100µF | +-(6.0%+10) |