620A ANENG
Digital Multimeter Transistor Tester Counts True RMS Automatic Electric Capacitance Meter Temperature Resistance
A. Overview:
Display: LCD
Max. Display value: 6000 digits
Auto power off time: 15 minutes
Power supply: 2 * 1.5V AAA Battery (Without)
The meter specifies one year as a cycle, And needs to be recalibrated below 18 ℃ ~ 28 ℃ , with relative humidity below 75%.
Display: LCD
Max. Display value: 6000 digits
Auto power off time: 15 minutes
Power supply: 2 * 1.5V AAA Battery (Without)
The meter specifies one year as a cycle, And needs to be recalibrated below 18 ℃ ~ 28 ℃ , with relative humidity below 75%.
B.Specification:
Function | Range | Precision |
AC Current | 6000mA / 10A | + – (1.0% reading + 8 digits) |
DC Current | 6000mA / 10A | + – (1.0% reading + 5 digits) |
DC Voltage | 6V / 60V / 600V | + – (0.5% reading + 3 digits) |
AC Voltage | 6V / 60V / 600V | + – (0.8% reading + 5 digits) |
Test line on-off | – | 1Ω |
Resistance | 600Ω / 6k Ω / 60k Ω / 600k Ω / 6M Ω / 60M Ω | + – (0.8% reading + 3 digits) |
Diode test | – | 1V |
Capacitor | 6nF | + – (10% reading + 40 digits) |
60 NF / 6uF / 60 UF / 600 UF / 6mF / 60 MF | + – (2.5% reading + 20 digits) | |
Temperature | -40 ~ 1000 ℃ | + – (1% reading + 3 ℃ ) |
-40 ~ 1832 ℉ | + – (1% reading + 3 ℉ ) | |
Frequency | 100Hz / 1000Hz | + – (1.0% reading + 5 digits) |
100Hz / 1000Hz |